OPTIMA-ONLINE.FR ≡ Esl Resursi Présentoir De Plancher En Bois Floor Care Accessories
  • Battery Testing Equipment

  • Classic Four-Range Battery Testing System

Classic Four-Range Battery Testing System

$67.88 $118.11
Classic Four-Range Battery Testing System Introduction: Application Areas:This battery testing system is widely used in universities, research institutes for the testing and research of button cells, small-capacity cells, simulated cells, battery materials, supercapacitors, and other electrochemical aspects. Testing Parameters: Charge-discharge curves, charge-discharge efficiency, battery capacity, specific capacity, cycle life, capacity decay curves, DCIR internal resistance, leakage current of supercapacitors, and other parameters. Voltage Range: Charging Voltage: 0V-5V; Discharging Voltage: -5V Current Range: Four automatic switching ranges: Range One: 1uA-0.1mA (±0.02% of FS) Range Two: 0.1mA-1mA (±0.02% of FS) Range Three: 1mA-10mA (±0.02% of FS) Range Four: 10mA-100mA (±0.02% of FS) Features of Battery Testing System: Thickness is only 7cm, each cabinet can accommodate 20 units of equipment (160 channels), and each unit has a customized LCD display screen showing equipment box number, range, channel number, and communication status. AD/DA upgraded to 24-bit/16-bit, achieving an accuracy of one part in five thousand, with a sampling speed increased from the original 3 seconds/point to 10 points/second. 3-inch custom LCD display screen mainly shows equipment information (box number, voltage range, current range, communication status, channel number, etc.), adjustable brightness, and synchronized display content with the equipment’s main control board. Technical Parameters: Image Model BT-2018R (Classic Four-Range Model) BT-2018A (Exquisite Four-Range Model) BT-2018AS (Testing Chamber Four-Range Model) Dimensions L×W×H 45cm×24cm×7cm L×W×H 45cm×29cm×7cm L×W×H 45cm×29cm×10cm Combination Quantity 20 units/cabinet with fixture trays 20 units/cabinet with fixture trays 10 units/cabinet Cabinet Structure Galvanized sheet material, spray plastic treatment Panel made of pure aluminum material, surface treated with sandblasting Indicator Lights Dual-color LED indicators, Three status colors Seven-color light ring design (red for charging, green for discharging, orange for stand-by, white for test completion, yellow for protection stop, etc.) Consistent colors with control software status information Basic Parameters Input Power Single-phase AC 220V ±10% / 50Hz; 25W AC Impedance ≥10MΩ Voltage Voltage Range Charging Voltage: 0V-5V; Discharging Voltage: -5V Voltage Accuracy Actual control accuracy: ±0.02% of FS; Stability: ±0.02% of FS Constant Voltage Cut-off Current ≤5uA Current Automatic Switching Range One: 1uA-0.1mA (±0.02% of FS),Range Two: 0.1mA-1mA (±0.02% of FS),Range Three: 1mA-10mA (±0.02% of FS),Range Four: 10mA-100mA (±0.02% of FS) Current Accuracy Actual control accuracy: ±0.02% of FS; Stability: ±0.02% of FS Charge/Discharge Charge Mode Constant current charge/constant voltage charge/rate charge/constant power charge/constant voltage limit charge Discharge Mode Constant current discharge/constant voltage discharge/constant resistance discharge/rate discharge/constant power discharge/constant voltage limit discharge Limit Conditions Voltage, current, relative time, capacity, -△V, rate current, capacity statistics C1, time statistics T1, counter N1, counter N2 Recording Recording Time Change Δt: 50ms – 3600s Voltage Change ΔU: 0.001mV – 5V Current Change ΔI: 0.001mA – 100mA Recording Frequency Maximum recording frequency 20Hz Test event recording e.g., run, stop, protection information, parameter reset, channel change, online calibration, etc. Cycle Cycle Number 1-99999 cycles Nested loop Nested loop with a maximum support of 3 layers Protection Operational Protection Supports power-off protection, communication interruption protection, computer crash protection, system crash protection Protection Conditions Delayed protection, overvoltage, undervoltage, overcurrent, overcapacity, overtemperature, single-cell overvoltage, single-cell undervoltage Alarm Methods Test completion reminder, safety protection alarm, abnormal error alarm, prompt message Hardware Features Channel Characteristics 8 channels/unit, independently programmable, no interference Control Mode Dual closed-loop structure for constant current and constant voltage sources, high-precision linear adjustment Input Impedance ≥10GΩ (The leakage current in standby mode is less than 0.1nA, and in the power-off state, the battery is completely disconnected from the device.) Reference Characteristics Uses a specialized benchmark integrated chip from the United States; temperature coefficient: 5ppm/°C (maximum) AD/DA AD:24bit;DA:16bit Screen Display Information 3-inch LCD (box number, voltage range, current range, communication status, channel number, etc.) adjustable brightness Communication Mode USB/RS485, using photoelectric isolation technology, supports up to 256 connections Cooling Mode Air cooling, fan speed supports program control, temperature control, and full-speed modes Connection Method Four-wire system, supports three-electrode measurement, button-type fixture, alligator clip, etc. (user selectable) Software Features Software Style Developed on the C# platform, WIN10 style, flat design, adapted to current popular operating habits Software Language Supports online switching between Chinese and English Test Plan Features Independent script for each plan (can be copied, created, modified, deleted, etc.), loop control, data analysis, centralized database management, real-time curves, curve comparison, etc. Step Editing Features Intelligently judges logical relationships based on the operating mode, prompts for erroneous operations, automatically fills in main parameters and cutoff condition parameters, can also be manually modified Mode Operation Features Start, stop, resume start, force jump, parameter reset, channel change, etc. DCIR Testing Supports point-to-point DCIR calculation Supercapacitor Has the function of supercapacitor testing, directly displays results in “farads F” units, can measure leakage current Display Resolution 6-digit effective digits (×.×××××) Data Presentation Coordinate curve (X, Y coordinates customizable), graphics, data list (process, details layered) Data Export Can be exported as EXCEL, TXT, graphics (specified step or specified cycle export) Data Save Supports saving of individual or multiple data, automatically creates a new folder for multiple data saves, automatically adds start time, box number, and channel number to the file name for easy data management Software Upgrade Supports remote network push and online upgrade Get In TouchFill out the form below — free quote and professional suggestion will be sent for reference very soon! Name Email* Message Send
Battery Testing Equipment

Battery Testing Equipment

  • Portable Rack for Holding Battery Testing System
    $78.71 $125.16
  • Testing Chamber BT-2018AS Battery Testing Equipment
    $62.84 $96.77
  • High Accuracy Voltage and Internal Resistance Tester of Battery Cells R203
    $80.45 $117.46
  • Classic Four-Range Battery Testing System
    $67.88 $118.11
  • Battery Testing System for Cylindrical and Pouch Cells
    $35.04 $51.5

© 2026 - OPTIMA-ONLINE.FR